Quick Answer
Calculate Flooded Evaporator Shell-and-Tube Heat Transfer Coefficient with Frost Penalty Estimator
Calculator
Result Interpretation
Flooded Evaporator Shell-and-Tube Heat Transfer Coefficient with Frost Penalty Estimator Calculator computes Effective overall heat transfer coefficient in W/(m^2*K) using the defined engineering formula and the input values provided.
Worked Example
Verified calculation
Given:
- Tube-side (refrigerant) boiling heat transfer coefficient = 3800
- Frost layer thermal resistance multiplier = 0.65
- Shell-side convective heat transfer coefficient = 1200
- Tube wall conductive resistance = 4.2E-5
- COP-based frost degradation factor = 0.82
- Shell-side fouling resistance = 0.00015
Expected Result:
- Effective overall heat transfer coefficient = 472.02145311947
Engineering Interpretation:
Under the given input conditions, the calculated result is: Effective overall heat transfer coefficient = 472.02145311947 W/(m^2*K).
The actual numerical result is computed by the Runtime engine using the persisted tool definition. The values shown here come from automatically validated test cases.
Formula / Method
effective overall heat transfer coefficient = (1 / (1 / (shell-side convective heat transfer coefficient * frost layer thermal resistance multiplier) + shell-side fouling resistance + tube wall conductive resistance + 1 / refrigerant)) * cop-based frost degradation factorFormula family: formula_refrigeration_flooded_evaporator_shell_and_tube_heat_transfer_coefficient_frost_buildup_penalty_estimator
Variables
| Symbol | Label | Role | Description |
|---|---|---|---|
| h_shell | Shell-side convective heat transfer coefficient | INPUT | Shell-side convective heat transfer coefficient |
| h_tube | Tube-side (refrigerant) boiling heat transfer coefficient | INPUT | Tube-side (refrigerant) boiling heat transfer coefficient |
| R_fouling_shell | Shell-side fouling resistance | INPUT | Shell-side fouling resistance |
| R_tube_wall | Tube wall conductive resistance | INPUT | Tube wall conductive resistance |
| f_frost | Frost layer thermal resistance multiplier | INPUT | Frost layer thermal resistance multiplier |
| cop_penalty | COP-based frost degradation factor | INPUT | COP-based frost degradation factor |
| U_eff | Effective overall heat transfer coefficient | OUTPUT | Effective overall heat transfer coefficient |
Calculation Steps
- Enter the shell-side convective heat transfer coefficient in W/(m^2*K).
- Enter the tube-side (refrigerant) boiling heat transfer coefficient in W/(m^2*K).
- Enter the shell-side fouling resistance in m^2*K/W.
- Enter the tube wall conductive resistance in m^2*K/W.
- Enter the frost layer thermal resistance multiplier in dimensionless.
- Enter the cop-based frost degradation factor in dimensionless.
- Step 1: Compute effective overall heat transfer coefficient.
- Read the effective overall heat transfer coefficient (W/(m^2*K)) from the results.
Engineering Summary
Calculate Flooded Evaporator Shell-and-Tube Heat Transfer Coefficient with Frost Penalty Estimator
Frequently Asked Questions
What does this calculator calculate?
The Flooded Evaporator Shell-and-Tube Heat Transfer Coefficient with Frost Penalty Estimator Calculator estimates Effective overall heat transfer coefficient based on the input parameters you provide
Why is shell-side convective heat transfer coefficient important in this calculation?
shell-side convective heat transfer coefficient is directly proportional to effective overall heat transfer coefficient. When you enter shell-side convective heat transfer coefficient in W/(m^2*K), the calculator uses it in the engineering formula to compute the output
How should I interpret the result effective overall heat transfer coefficient?
The calculator outputs effective overall heat transfer coefficient in W/(m^2*K). The result is computed directly from the input values using the defined engineering formula
What units should I use for the inputs?
Enter each value in the units shown next to the input field: Shell-side convective heat transfer coefficient (W/(m^2*K)), Tube-side (refrigerant) boiling heat transfer coefficient (W/(m^2*K)), Shell-side fouling resistance (m^2*K/W), Tube wall conductive resistance (m^2*K/W), Frost layer thermal resistance multiplier (dimensionless), COP-based frost degradation factor (dimensionless). Make sure all inputs use the specified units for consistent results
What assumptions does this calculator use?
This calculator uses automatically validated engineering formulas. Results are approximate and should be validated against site-specific conditions, applicable codes, and professional engineering judgment
Related Tools
Browse More Tools
Explore the full index of engineering calculators on this vertical site.